Product name:JC-YZ-400 Atomic Absorption Spectrophotometer -
Order number: -
Model:JC-YZ-400 -
Stock status:Delivery according to contract -
Logistics:by sea, by air, by express, etc.
- Product Introduction
- Details Page
-
1. Product introduction
1. Optical system
wavelength range
185nm—910nm automatic adjustment
Grating line density
1800 lines/mm
Monochromator
Aberration Czerny-Turner Monochromator
Spectral bandwidth
0.1, 0.2, 0.4, 1.0, 2.0nm, multi-speed automatic switching
Wavelength accuracy
±0.10nm
wavelength repeatability
0.05nm
baseline drift
Static 0.002A/30min Dynamic 0.006 A/30min
Detector
Wide spectral range photomultiplier tube
Resolution
To distinguish 279.5nm and 279.8nm double lines of manganese lamps , the valley energy between the two spectral lines should be less than 20%
2. Light source system
lamp holder
3 lamp sockets
Lamp power supply mode
400Hz square wave pulse
Lamp current adjustment range
2— 10mA average current
3. Atomic system
Flameless (graphite furnace) analytical method
Detection limit ( Cd)
≤4pg
4. Flameless (graphite furnace) analysis method
Measurement methods
Graphite furnace peak height method, graphite furnace peak area method
background correction
Deuterium lamp background correction is greater than 60 times, and self-absorption deduction background is greater than 60 times
Repeat measurement times
1-30 times, calculate the mean, give the standard deviation and relative standard deviation
result print
Print test data or final analysis report. The results can be exported to an Excel worksheet.
Software Environment
Windows XP/ Windows 7 operating system, Chinese professional software
2. Product parameters
power supply
AC 220V/50HZ
power
150VA
Instrument net weight
55kg
Instrument gross weight
80kg
Instrument volume
1110mm (horizontal) × 400mm (depth) × 500mm (height)
package volume
1350mm (horizontal) × 600mm (depth) × 850mm (height)
Working temperature
10~35℃
Working environment humidity
≤80%
3. Product Features
1. Total reflection optical system, full-band achromatic, automatic wavelength scanning and automatic peak finding.
2. With deuterium lamp button background, self-priming button background.
3. Automatically adjust negative high voltage, lamp current, element lamp position, and adjust energy at will to maximize.
3 hollow cathode lamp holders. Automatic control system, fully automatic scanning wavelength.
1 element lamp works and the other 2 element lamps are preheated.
4. Graphite furnace heating: users can freely set the heating curve according to their needs.
Advanced graphite furnace constant power temperature control design: the temperature of the graphite tube is uniform and consistent, and the working temperature of the graphite tube maintains a good dynamic stability to ensure the accuracy of the analysis.