- Industry Solutions
-
Occupational Hygiene Testing---Procurement Plan
Test items
product name
Common models
Product Specifications
standard
Airborne dust, gas
Personal gas sampler
GQC-1
20-300ml/min
GBZ/T300.XX-2017
Personal gas sampler
GQC-2
20-300ml/min, explosion-proof
GBZ/T300.XX-2017
Gas sampler
QC-1S
0.1~1.5L/min
GBZ/T300.XX-2017
Explosion-proof atmospheric sampler
QC-4S
0.1~1.5L/min, explosion-proof
GBZ/T300.XX-2017
Atmospheric sampler
QC-5
1.0~5.0L/min
GBZ/T300.XX-2017
Personal dust/air sampler
GFC -5
1.0~5.0L/min
GBZ/T 192 Determination of Dust in Workplace Air
Personal dust/air sampler
GFC-5B
1.0~5.0L/min, explosion-proof
GBZ/T 192 Determination of Dust in Workplace Air
Dust sampler
FC-1A
5~30L/min
GBZ/T192.1
Dust sampler (explosion-proof)
IFC-2
5.0~25L/min (customizable 5.0~30L/min) Detection of exhaled dust and total dust
The explosion-proof mark is Ex(ib) II AT3, which can be used in the environment of Class II explosive gas specified by the state.
Various air sample collectors
bullae absorber
10mL/25mL/50mL
colorless/brown
Use with a sampler to collect different gases and choose bottles of different colors and types
vesicle absorber
10mL/25mL/50mL
colorless/brown
Glass plate absorber
10mL/25mL/50mL
colorless/brown
Shock Absorber
20mL/100mL/200mL
colorless/brown
Calibration flow
Electronic soap film flowmeter
JCL-2010(A)
10-1000mL/min
/
Electronic soap film flowmeter
JCL-2010(D)
0.1-30L/min for calibrating dust sampler
/
dust, dust
Microcomputer dust meter
LD-5H
0-10MG/M3, PM10, PM2.5
Industrial Enterprise Hygiene Standard (GBZ1-2010), Workplace Hazardous Factor Exposure Limit (GBZ2-2002) Standard, Ministry of Health WS/T206-2001, Ministry of Labor LD98-1996, Ministry of Health Health Supervision [2006] No. 58
pressure
Empty Box Barometer
DYM3
plain
Relative humidity
Mechanical ventilation psychrometer
DHM2
10%RH~100%RH;-36℃~46℃
Wet and dry ball method GB/T 18204.1-2013
wind speed
hot bulb anemometer
QDF-6
0-30m/s
Heat radiation
bolometer
MR-5
0~10KW/㎡
For the measurement of radiant heat in public places; applicable standard: GB/T 18204.1-2013
temperature
Black and wet bulb thermometers
WBGT-2006
Data analysis software not included
For occupational hygiene high temperature measurement; applicable standard: GBZ/T 189.7-2007
noise
Octave Sound Level Meter
AWA5688
Configuration 2, statistics, storage, with printing
GB/T 18204.1-2013
personal sound exposure meter
ASV5910-1
(Configuration 1, 2, a single set of simple configuration)
For occupational health individual noise measurement; applicable standard: GBZT 189.8-2007.
sound level calibrator
AWA6021A
Calibrated Class 1, Class 2 Sound Level Meters
multifunction sound level meter
AWA6228+
Level 1, statistics, storage, 1/1OCT analysis, with AH40 printer
For environmental and social life noise measurement; applicable standard: GB 22337-2008
vibration
Hand Vibration Tester
AWA6256B+
Configuration 2, measurement of environmental vibration and human vibration, including printer
GBZ/T 189.9-2007
Temperature and humidity
Digital Thermo-Hygrometer
TES-1360A
Humidity: 10%~95%RH Temperature: -20℃~+60℃(-4℉~+140℉)
/
Field strength
High-frequency near-field electromagnetic field tester
RJ-2
Frequency range: 20~200MHz, Measurement range: 0~450V/m
For the measurement of occupational health high-frequency electromagnetic fields; applicable standard: GBZ/T 189.2-2007
Power frequency electric field measuring instrument
RJ-5
Frequency: 30HZ-2000Hz, electric field: 1-20KV/M
For occupational health power frequency electric field measurement; applicable standard: GBZ/T 189.3-2007
microwave radiation
Microwave leakage meter
ML-91VA
Probe: 0.9GHz-6GHz (standard)
For the measurement of occupational health microwave radiation; applicable standard: GBZ/T 189.5-2007
UV radiation
UV meter
UV-B
dual channel
For the measurement of occupational health UV radiation and public places UV radiation; applicable standards: GBZ/T 189.6-2007, GB/T 18204.1-2013 (14)
UV meter
UV-A
single channel
personal radiation
Radioactive Personal Dose Alarm
RG1100
0.01μSv/h~1mSv/h
environmental radiation
Intelligent X-gamma radiation measuring instrument
JB4000
0.01μGy/h~600μGy/h
For the measurement of ionizing radiation; applicable standards: GB/T 14583-1993, HJ/T 61-2001
carbon monoxide
Spectroscopic Infrared CO Analyzer
JC-3011A
Built-in pump suction, 0-50ppm/100ppm
For CO detection and analysis, use standard: GBZ/T300.35-2017
carbon dioxide
Spectroscopic Infrared CO2 Analyzer
JC-3010E (S)
At the same time, it can detect indoor CO2 concentration, temperature and humidity
For CO2 detection and analysis, applicable standard: GBZ/T300.35-2017
formaldehyde
Formaldehyde analyzer
4160-II
Detection range: 0.00-19.99PPM; Resolution: 0.01; Measurement accuracy: 0.01PPM;
Radon gas
Radon meter
FD216
It has four functions of measuring soil radon, air radon, water radon concentration (optional) and radon precipitation rate (optional).
Applicable standards: GB50325-2010, GB/T16147-1995
Laboratory support
Spectrophotometer
721
610nm
autoclave
24L
24L
Water bath
HH series-6
6 holes
One thousandth balance
JC5003CH
500g/1mg
Vortex mixer
JC-XW-I
Standard
Vortex Shaker
JC-GGC-12H
roundabout
pH meter
PHB-4
Standard
Colony Counter
XK97-A
Standard
Heated Incubators
HN series-50BS
45*55*55
C02 incubator
JC-CHP-80S
80L
Microscope
XSP-2CA
binocular
centrifuge
TDL-4
20ml
Homogenizer
JC-JZ-08
Contains 50 Homogenized Bags