/uploadfiles/site/img/20220304/6221a52bdbbcd.png

PRODUCTS CENTER

Service Hotline
+86-532-80921517
Conce.nitrogen blow.
Electrical heating nitrogen blower
Electrical heating nitrogen blower
JC-220 Electrical heating nitrogen blower
  • Product name:JC-220 Electrical heating nitrogen blower
  • Order number:
  • Model:JC-220C-12/24
  • Stock status:Available
  • Logistics:By sea, air, express, etc.
  • Product Introduction
  • Product parameters
  • JC-220 changeable modules
  • 1. Product introduction

     Generally, it is used for the pretreatment of gas phase and liquid phase experiments, instead of the commonly used rotary evaporator for concentration, it can concentrate dozens of samples at the same time, which greatly shortens the sample preparation time.

     

    2. Product Features

     

    1. The heater enables the sample to be quickly and efficiently heated to the evaporation temperature, and at the same time, the gas is blown from the gas chamber to the surface of the solution through the gas needle, which promotes the rapid evaporation of the solution and the concentration of the sample.

     

    2. Instant temperature display and time decrement display.

     

    3. The whole working system consists of adjustable gas chamber and heater.

     

    4. The position of the gas needle in the gas chamber can be changed to make it suitable for different test tubes. The standard gas needle length is 150mm.

     

    5. The height of the air cavity can be adjusted according to the height of the solvent liquid level. When concentrating toxic solvents, the entire system can be placed in a fume hood.

     

    6. Automatic fault detection and alarm function.

     

    7. Standard equipped with air cavity and special adjustable bracket.

     

    8. Built-in over-temperature protection device.

  • 1. Temperature range: room temperature +5℃~150℃;

     

    2. Heating time: ≤30min (from 40℃ to 150℃);

     

    3. Temperature accuracy: 40~100℃: ±0.5℃;

     

    4. Temperature accuracy: 100~150℃: ±1℃;

     

    5. Temperature stability: 100±0.5℃;

     

    6. Number of modules: 1 module for JC-220-1 type, 2 modules for JC-220-2 type;

     

    7. Display accuracy: 0.1;

     

    8. The longest time setting: 99h59min;

     

    9. Display: LED;

     

    10. Nitrogen flow: 0~10L/min;

     

    11. Nitrogen pressure: ≤0.1MPa;

     

    12. Module model selection: see JC-220 series replaceable modules.

     

  • Model

    Test tube Dia.

    Tube quantity

    Module size mm

    01

    6 mm

    49

    96x96x49

    02

    7 mm

    49

    96x96x49

    03

    10 mm

    25

    96x96x49

    04

    12 mm

    25

    96x96x49

    05

    13 mm

    25

    96x96x49

    06

    15 mm

    12

    96x96x49

    07

    15 mm

    16

    96x96x49

    08

    16 mm

    12

    96x96x49

    09

    16 mm

    16

    96x96x49

    10

    19 mm

    12

    96x96x49

    11

    19 mm

    16

    96x96x49

    12

    20 mm

    9

    96x96x49

    13

    26 mm

    9

    96x96x49

    14

    28 mm

    4

    96x96x49

    15

    40 mm

    4

    96x96x49

    16

    0.5 ml centrifuge tube

    49

    96x96x49

    17

    1.5 ml centrifuge tube

    25

    96x96x49

    18

    2.0 ml centrifuge tube

    25

    96x96x49