/uploadfiles/site/img/20220304/6221a52bdbbcd.png

PRODUCTS CENTER

Service Hotline
+86-532-80921517
Sampling gun
sampling tube
sampling tube
JC-YQ-17 Pollution source exhaust gas multifunctional sampling tube
  • Product name:JC-YQ-17 Pollution source exhaust gas multifunctional sampling tube
  • Order number:
  • Model:JC-YQ-17
  • Stock status:Delivery according to contract
  • Logistics:by sea, by air, by express, etc.
  • Product Introduction
  • 1. Technical features


    Integrated whole process heating bong with beautiful appearance;
    sampling tube is lined with PTFE tube to avoid pipeline adsorption;
    filter membrane holder is made of PTFE material, which automatically maintains a constant temperature of 120 ℃ during sampling;
    supporting tube Circuit closing device, which is convenient for closing the gas circuit;
    high-efficiency incubator, which can be placed in various combinations of absorption bottles;
    can be used for both horizontal flue sampling and vertical flue sampling;
    low-voltage DC power supply, safe and reliable use;
    imported high-precision temperature Controller, high-power power supply, fast heating to constant temperature;
    multi-function combined sampling gun, including smoke temperature and pitot tube flow rate measurement function;
    multi-purpose gun, can collect hydrochloric acid, sulfuric acid, hydrogen fluoride (fluoride), bromide Hydrogen, chromate and other pollutants;


    2. Technical parameters


    The main parameters

    parameter

    constant temperature

    (80 ~ 200)℃, error ±3℃

    Heating time

    <20min

    Sampling tube length

    1.5m

    Sampling nozzle diameter

    Φ4.5/Φ6/Φ7/Φ8/Φ10/Φ12

    membrane diameter

    Φ47

    Absorption bottle specifications

    250ml/75ml impact absorption bottle

    power supply

    DC24V

    Power consumption

    <400W

    weight

    ≈8.0kg

Recommended Products