JC-YZ-600 Flame Graphite Furnace Integrated Atomic Absorption Spectrophotometer
  • Product name:JC-YZ-600 Flame Graphite Furnace Integrated Atomic Absorption Spectrophotometer
  • Order number:
  • Model:JC-YZ-600
  • Stock status:Delivery according to contract
  • Logistics:by sea, by air, by express, etc.
  • Product Introduction
  • Details Page
  • 1.Product introduction 


    1. Optical system


    wavelength range

    185nm910nm automatic adjustment

    Grating line density

    1800 lines/mm

    Monochromator

    Aberration Czerny-Turner Monochromator

    Spectral bandwidth

    0.1, 0.2, 0.4, 1.0, 2.0nm, multi-speed automatic switching

    Wavelength accuracy

    ±0.10nm

    wavelength repeatability

    0.05nm

    baseline drift

    Static ±0.002A/30min Dynamic ±0.006 A/30min

    Detector

    Wide spectral range photomultiplier tube

    Resolution

    To distinguish 279.5nm and 279.8nm double lines of manganese lamps , the valley energy between the two spectral lines should be less than 20%


    2. Light source system


    lamp holder

    8 lamp holder automatic switching

    Lamp power supply mode

    400Hz square wave pulse

    Lamp current adjustment range

    2 10mA average current


    3. Atomic system


    flame analysis method

    Detection limit (Cu)

    <0.003μg/ml

    Characteristic concentration (Cu)

    <0.015μg/ml/1%

    burner

    100mm full titanium burner

    Precision

    RSD<0.5%

    sprayer

    Metal Sleeve High Efficiency Glass Sprayer

    spray chamber

    Corrosion-resistant all-plastic spray chamber

    safety measures

    With a variety of automatic safety protection functions: acetylene leakage alarm, automatic shutdown system, etc.

    Flameless (graphite furnace) analytical method

    Detection limit ( Cd)

    <0.4*10ˉ12 g

    Feature quantity ( Cd)

    <0.5*10ˉ12 g

    Hydride Generation - Atomic Absorption


    4. Flame analysis method


    Measurement methods

    Air -acetylene flame method

    Concentration calculation method

    Standard curve method, standard addition method, interpolation method.

    Repeat measurement times

    From 1 to 99 times, the average value, content, standard deviation and relative standard deviation are automatically calculated.

    result print

    Print test data or final analysis report. The results can be exported to a word worksheet.

    Software Environment

    Windows XP/ Windows 7 operating system, Chinese professional software


    5. Flameless (graphite furnace) analysis method


    Measurement methods

    Graphite furnace peak height method, graphite furnace peak area method

    Concentration calculation method

    Standard curve method, standard addition method, interpolation method.

    background correction

    Deuterium lamp background correction is greater than 60 times, and self-absorption deduction background is greater than 60 times

    Repeat measurement times

    1-30 times, calculate the mean, give the standard deviation and relative standard deviation

    result print

    Print test data or final analysis report. The results can be exported to a word worksheet.

    Software Environment

    Windows XP/ Windows 7 operating system, Chinese professional software

    2. Product parameters

    power supply

    AC 220V/50HZ

    power

    150VA

    Instrument net weight

    55kg

    Instrument gross weight

    80kg

    Instrument volume

    1110mm (horizontal) × 400mm (depth) × 500mm (height)

    package volume

    1350mm (horizontal) × 600mm (depth) × 850mm (height)

    Working temperature

    10~35

    Working environment humidity

    80%

    3. Product Features 


    1. Total reflection optical system, full-band achromatic, automatic wavelength scanning and automatic peak finding. 


    2. With deuterium lamp button background, self-priming button background. 


    3. The uniquely designed all-titanium burner has smooth combustion and fast heat balance. 


    4. Automatic adjustment of negative high voltage, lamp current, automatic adjustment of the best element lamp position, automatic ignition, automatic flameout protection. 8 lamp stands (optional 2 high-performance lamps) automatic control system, which can adjust the hollow cathode lamp to the best position in all directions, can set the lamp position of a specific element independently, and can freely set the working lamp, preheating The lamp saves the element lamp preparation time to the greatest extent possible. 


    5. Graphite furnace heating: users can freely set the heating curve according to their needs. Advanced graphite furnace constant power temperature control design: the temperature of the graphite tube is uniform and consistent, and the working temperature of the graphite tube maintains a good dynamic stability to ensure the accuracy of the analysis.